68 research outputs found

    New Mechatronic Systems for the Diagnosis and Treatment of Cancer

    Get PDF
    Both two dimensional (2D) and three dimensional (3D) imaging modalities are useful tools for viewing the internal anatomy. Three dimensional imaging techniques are required for accurate targeting of needles. This improves the efficiency and control over the intervention as the high temporal resolution of medical images can be used to validate the location of needle and target in real time. Relying on imaging alone, however, means the intervention is still operator dependent because of the difficulty of controlling the location of the needle within the image. The objective of this thesis is to improve the accuracy and repeatability of needle-based interventions over conventional techniques: both manual and automated techniques. This includes increasing the accuracy and repeatability of these procedures in order to minimize the invasiveness of the procedure. In this thesis, I propose that by combining the remote center of motion concept using spherical linkage components into a passive or semi-automated device, the physician will have a useful tracking and guidance system at their disposal in a package, which is less threatening than a robot to both the patient and physician. This design concept offers both the manipulative transparency of a freehand system, and tremor reduction through scaling currently offered in automated systems. In addressing each objective of this thesis, a number of novel mechanical designs incorporating an remote center of motion architecture with varying degrees of freedom have been presented. Each of these designs can be deployed in a variety of imaging modalities and clinical applications, ranging from preclinical to human interventions, with an accuracy of control in the millimeter to sub-millimeter range

    Prognostic implications of left ventricular global longitudinal strain in heart failure patients with narrow QRS complex treated with cardiac resynchronization therapy: a subanalysis of the randomized EchoCRT trial

    Get PDF
    Aim: Left ventricular (LV) global longitudinal strain (GLS) reflects LV systolic function and correlates inversely with the extent of LV myocardial scar and fibrosis. The present subanalysis of the Echocardiography Guided CRT trial investigated the prognostic value of LV GLS in patients with narrow QRS complex. Methods and results: Left ventricular (LV) global longitudinal strain (GLS) was measured on the apical 2-, 4- and 3-chamber views using speckle tracking analysis. Measurement of baseline LV GLS was feasible in 755 patients (374 with cardiac resynchronization therapy (CRT)-ON and 381 with CRT-OFF). The median value of LV GLS in the overall population was 7.9%, interquartile range 6.2–10.1%. After a mean follow-up period of 19.4 months, 95 patients in the CRT-OFF group and 111 in the CRT-ON group reached the combined primary endpoint of all-cause mortality and heart failure hospitalization. Each 1% absolute unit decrease in LV GLS was independently associated with 11% increase in the risk to reach the primary endpoint (Hazard ratio 1.11; 95% confidence interval 95% 1.04–1.17, P < 0.001), after adjusting for ischaemic cardiomyopathy and randomization treatment among other clinically relevant variables. When categorizing patients according to quartiles of LV GLS, the primary endpoint occurred more frequently in patients in the lowest quartile (<6.2%) treated with CRT-ON vs. CRT-OFF (45.6% vs. 28.7%, P = 0.009) whereas, no differences were observed in patients with LV GLS ≥6.2% treated with CRT-OFF vs. CRT-ON (23.7% vs. 24.5%, respectively; P  = 0.62). Conclusion: Low LV GLS is associated with poor outcome in heart failure patients with QRS width <130 ms, independent of randomization to CRT or not. Importantly, in the group of patients with the lowest LV GLS quartile, CRT may have a detrimental effect on clinical outcomes

    The effect of QRS duration on cardiac resynchronization therapy in patients with a narrow QRS complex: a subgroup analysis of the EchoCRT trial

    Get PDF
    Aims In EchoCRT, a randomized trial evaluating the effect of cardiac resynchronization therapy (CRT) in patients with a QRS duration of <130 ms and echocardiographic evidence of left ventricular dyssynchrony, the primary outcome occurred more frequently in the CRT when compared with the control group. According to current heart failure guidelines, CRT is recommended in patients with a QRS duration of ≥120 ms. However, there is some ambiguity from clinical trial data regarding the benefit of patients with a QRS duration of 120-130 ms. Methods and results The main EchoCRT trial was prematurely terminated due to futility. For the current subgroup analysis we compared data for CRT-ON vs. -OFF in patients with QRS < 120 (n = 661) and QRS 120-130 ms (n = 139). On uni- and multivariable analyses, no significant interaction was observed between the two groups and randomized treatment for the primary or any of the secondary endpoints. On multivariable analysis, a higher risk for the primary endpoint was observed in patients with a QRS duration of 120-130 ms randomized to CRT-ON vs. CRT-OFF (hazard ratio 2.18, 95% CI 1.02-4.65; P = 0.044). However, no statistically significant interaction, compared with patients with QRS < 120 ms randomized to CRT-ON vs. CRT-OFF, was noted (P-interaction = 0.160). Conclusions In this pre-specified subgroup analysis of EchoCRT, no benefit of CRT was evident in patients with a QRS duration of 120-130 ms. These data further question the usefulness of CRT in this patient populatio

    Cardiac resynchronization therapy in patients with heart failure and narrow QRS complexes

    Get PDF
    Background: Cross correlation analysis (CCA) using tissue Doppler imaging has been shown to be associated with outcome after cardiac resynchronization therapy (CRT) in patients with heart failure (HF) with wide QRS. However, its significance in patients with narrow QRS treated with CRT is unknown. Objectives: The aim of the current study was to investigate the association of mechanical activation delay by CCA with study outcome in patients with HF enrolled in the EchoCRT trial. Methods: Baseline CCA could be performed from tissue Doppler imaging in the apical views in 807 of 809 (99.7%) enrolled patients, and 6-month follow-up could be performed in 610 of 635 (96%) patients with available echocardiograms. Patients with a pre-specified maximal activation delay ≥35 ms were considered to have significant delay. The study outcome was HF hospitalization or death. Results: Of 807 patients, 375 (46%) did not have delayed mechanical activation at baseline by CCA. Patients without delayed mechanical activation who were randomized to CRT-On compared with CRT-Off had an increased risk of poor outcome (hazard ratio: 1.70; 95% confidence interval: 1.13 to 2.55; p = 0.01) with a significant interaction term (p = 0.04) between delayed mechanical activation and device randomization for the endpoint. Among patients with paired baseline and follow-up data with no events before 6-month follow-up (n = 541), new-onset delayed mechanical activation in the CRT-On group showed a significant increase in unfavorable events (hazard ratio: 3.73; 95% confidence interval: 1.15 to 12.14; p = 0.03). Conclusions: In the EchoCRT population, absence of delayed mechanical activation by CCA was significantly associated with poor outcomes, possibly due to the onset of new delayed mechanical activation with CRT pacing. (Echocardiography Guided Cardiac Resynchronization Therapy [EchoCRT] Trial; NCT00683696)

    Marine Biodiversity in the Australian Region

    Get PDF
    The entire Australian marine jurisdictional area, including offshore and sub-Antarctic islands, is considered in this paper. Most records, however, come from the Exclusive Economic Zone (EEZ) around the continent of Australia itself. The counts of species have been obtained from four primary databases (the Australian Faunal Directory, Codes for Australian Aquatic Biota, Online Zoological Collections of Australian Museums, and the Australian node of the Ocean Biogeographic Information System), but even these are an underestimate of described species. In addition, some partially completed databases for particular taxonomic groups, and specialized databases (for introduced and threatened species) have been used. Experts also provided estimates of the number of known species not yet in the major databases. For only some groups could we obtain an (expert opinion) estimate of undiscovered species. The databases provide patchy information about endemism, levels of threat, and introductions. We conclude that there are about 33,000 marine species (mainly animals) in the major databases, of which 130 are introduced, 58 listed as threatened and an unknown percentage endemic. An estimated 17,000 more named species are either known from the Australian EEZ but not in the present databases, or potentially occur there. It is crudely estimated that there may be as many as 250,000 species (known and yet to be discovered) in the Australian EEZ. For 17 higher taxa, there is sufficient detail for subdivision by Large Marine Domains, for comparison with other National and Regional Implementation Committees of the Census of Marine Life. Taxonomic expertise in Australia is unevenly distributed across taxa, and declining. Comments are given briefly on biodiversity management measures in Australia, including but not limited to marine protected areas

    Chlamydia trachomatis Strains Show Specific Clustering for Men Who Have Sex with Men Compared to Heterosexual Populations in Sweden, the Netherlands, and the United States

    Get PDF
    High-resolution genotyping of Chlamydia trachomatis improves the characterization of strains infecting different patient groups and sexual networks. In this study, multilocus sequence typing (MLST) and ompA sequence determination were used for an analysis of C. trachomatis strains from 203 men who have sex with men (MSM) from Sweden, the Netherlands, and the United States. The results obtained were compared with data from 153 heterosexual women from Sweden and the Netherlands. The overlap in MLST/ompA profiles between MSM from Sweden and the Netherlands was 68%, while the overlap between heterosexual populations from these countries was only 18%. The distribution of genotypes in MSM from the United States was less similar to that in MSM from the European countries, with 45% and 46% overlaps for MSM in Sweden and the Netherlands, respectively. Minimum-spanning-tree analysis of MLST/ompA sequence types identified two large clusters that contained almost exclusively samples from MSM and comprised 74% of all MSM samples. Three other clusters were predominated by samples from women but also contained MSM specimens. Of 19 detected variants of the MLST target CT144, three variants were highly associated with MSM. Our study supports the hypotheses of both tissue tropism as well as epidemiological network structures as explanations for the linkage between specific genetic variants and sexual orientation

    Comprehensive Fragment Screening of the SARS-CoV-2 Proteome Explores Novel Chemical Space for Drug Development

    Get PDF
    12 pags., 4 figs., 3 tabs.SARS-CoV-2 (SCoV2) and its variants of concern pose serious challenges to the public health. The variants increased challenges to vaccines, thus necessitating for development of new intervention strategies including anti-virals. Within the international Covid19-NMR consortium, we have identified binders targeting the RNA genome of SCoV2. We established protocols for the production and NMR characterization of more than 80 % of all SCoV2 proteins. Here, we performed an NMR screening using a fragment library for binding to 25 SCoV2 proteins and identified hits also against previously unexplored SCoV2 proteins. Computational mapping was used to predict binding sites and identify functional moieties (chemotypes) of the ligands occupying these pockets. Striking consensus was observed between NMR-detected binding sites of the main protease and the computational procedure. Our investigation provides novel structural and chemical space for structure-based drug design against the SCoV2 proteome.Work at BMRZ is supported by the state of Hesse. Work in Covid19-NMR was supported by the Goethe Corona Funds, by the IWBEFRE-program 20007375 of state of Hesse, the DFG through CRC902: “Molecular Principles of RNA-based regulation.” and through infrastructure funds (project numbers: 277478796, 277479031, 392682309, 452632086, 70653611) and by European Union’s Horizon 2020 research and innovation program iNEXT-discovery under grant agreement No 871037. BY-COVID receives funding from the European Union’s Horizon Europe Research and Innovation Programme under grant agreement number 101046203. “INSPIRED” (MIS 5002550) project, implemented under the Action “Reinforcement of the Research and Innovation Infrastructure,” funded by the Operational Program “Competitiveness, Entrepreneurship and Innovation” (NSRF 2014–2020) and co-financed by Greece and the EU (European Regional Development Fund) and the FP7 REGPOT CT-2011-285950—“SEE-DRUG” project (purchase of UPAT’s 700 MHz NMR equipment). The support of the CERM/CIRMMP center of Instruct-ERIC is gratefully acknowledged. This work has been funded in part by a grant of the Italian Ministry of University and Research (FISR2020IP_02112, ID-COVID) and by Fondazione CR Firenze. A.S. is supported by the Deutsche Forschungsgemeinschaft [SFB902/B16, SCHL2062/2-1] and the Johanna Quandt Young Academy at Goethe [2019/AS01]. M.H. and C.F. thank SFB902 and the Stiftung Polytechnische Gesellschaft for the Scholarship. L.L. work was supported by the French National Research Agency (ANR, NMR-SCoV2-ORF8), the Fondation de la Recherche Médicale (FRM, NMR-SCoV2-ORF8), FINOVI and the IR-RMN-THC Fr3050 CNRS. Work at UConn Health was supported by grants from the US National Institutes of Health (R01 GM135592 to B.H., P41 GM111135 and R01 GM123249 to J.C.H.) and the US National Science Foundation (DBI 2030601 to J.C.H.). Latvian Council of Science Grant No. VPP-COVID-2020/1-0014. National Science Foundation EAGER MCB-2031269. This work was supported by the grant Krebsliga KFS-4903-08-2019 and SNF-311030_192646 to J.O. P.G. (ITMP) The EOSC Future project is co-funded by the European Union Horizon Programme call INFRAEOSC-03-2020—Grant Agreement Number 101017536. Open Access funding enabled and organized by Projekt DEALPeer reviewe

    Streptococcus pneumoniae Resistance to Complement-Mediated Immunity Is Dependent on the Capsular Serotype ▿

    No full text
    Streptococcus pneumoniae strains vary considerably in the ability to cause invasive disease in humans, and this is partially associated with the capsular serotype. The S. pneumoniae capsule inhibits complement- and phagocyte-mediated immunity, and differences between serotypes in these effects on host immunity may cause some of the variation in virulence between strains. However, the considerable genetic differences between S. pneumoniae strains independent of the capsular serotype prevent an unambiguous assessment of the effects of the capsular serotype on immunity using clinical isolates. We have therefore used capsular serotype-switched TIGR4 mutant strains to investigate the effects of the capsular serotype on S. pneumoniae interactions with complement. Flow cytometry assays demonstrated large differences in C3b/iC3b deposition on opaque-phase variants of TIGR4(−)+4, +6A, +7F, and +23F strains even though the thicknesses of the capsule layers were similar. There was increased C3b/iC3b deposition on TIGR4(−)+6A and +23F strains compared to +7F and +4 strains, and these differences persisted even in serum depleted of immunoglobulin G. Neutrophil phagocytosis of the TIGR4(−)+6A and +23F strains was also increased, but only in the presence of complement, showing that the effects of the capsular serotype on C3b/iC3b deposition are functionally significant. In addition, the virulence of the TIGR4(−)+6A and +23F strains was reduced in a mouse model of sepsis. These data demonstrate that resistance to complement-mediated immunity can vary with the capsular serotype independently of antibody and of other genetic differences between strains. This might be one mechanism by which the capsular serotype can affect the relative invasiveness of different S. pneumoniae strains

    Clinical Trial Design Principles and Endpoint Definitions for Transcatheter Mitral Valve Repair and Replacement: Part 1: Clinical Trial Design Principles: A Consensus Document From the Mitral Valve Academic Research Consortium.

    Full text link
    Mitral regurgitation (MR) is one of the most prevalent valve disorders and has numerous etiologies, including primary (organic) MR, due to underlying degenerative/structural mitral valve (MV) pathology, and secondary (functional) MR, which is principally caused by global or regional left ventricular remodeling and/or severe left atrial dilation. Diagnosis and optimal management of MR requires integration of valve disease and heart failure specialists, MV cardiac surgeons, interventional cardiologists with expertise in structural heart disease, and imaging experts. The introduction of transcatheter MV therapies has highlighted the need for a consensus approach to pragmatic clinical trial design and uniform endpoint definitions to evaluate outcomes in patients with MR. The Mitral Valve Academic Research Consortium is a collaboration between leading academic research organizations and physician-scientists specializing in MV disease from the United States and Europe. Three in-person meetings were held in Virginia and New York during which 44 heart failure, valve, and imaging experts, MV surgeons and interventional cardiologists, clinical trial specialists and statisticians, and representatives from the U.S. Food and Drug Administration considered all aspects of MV pathophysiology, prognosis, and therapies, culminating in a 2-part document describing consensus recommendations for clinical trial design (Part 1) and endpoint definitions (Part 2) to guide evaluation of transcatheter and surgical therapies for MR. The adoption of these recommendations will afford robustness and consistency in the comparative effectiveness evaluation of new devices and approaches to treat MR. These principles may be useful for regulatory assessment of new transcatheter MV devices, as well as for monitoring local and regional outcomes to guide quality improvement initiatives
    corecore